ControlByWeb
Product Catalog   (435) 750-5999
VEGAPOINT Limit Switches
5 Year Warranty

The VEGAPOINT Series are low-cost, low power consumption, ultra-compact capacitive limit switches that are perfect for basic liquid level monitoring

APPLICATION AREA

From DK > 2, 1/2" NPT thread, M12, transistor output

Configurable: Please contact our sales department for additional options.

IMAGE

VEGAPOINT 11

PRICE

$207.00

Lead Time: 2-4 Weeks

Quantity:

Application Area

The VEGAPOINT Series of ultra-compact capacitive limit switches are your best option for liquid detection. This series can be very easily installed in a number of different applications, including the food, beverage, and pharmaceutical industries. The low-cost, low power consumption designs of the VEGAPOINT Series products provide high-end results.

Your benefit

  • High plant availability through non-contact measurement
  • Exact measurement results independent of medium properties and process conditions
  • Maintenance-free operation due to non-contact 80 GHz radar technology

Mineralization Tank

Point Level Detection

Various methods are used to replenish the demineralised water with the minerals required in healthy drinking water. One method is to pass the water through a container filled with limestone, enriching it with mineral substances. The filling of the container is monitored with the help of a point level switch.

Reliable

Approved materials according to FDA and EC 1935/2004 regulations as well as country-specific approvals

Storage Container

Storing Yeast

The yeast is grown and stored in small storage tanks at an optimal temperature, then added to the fermentation tanks as required. To ensure ideal storage, the minimum and maximum limit levels as well as the pressure in the tank are monitored.

Doncenser

Condenser pressure and point level measurement

In the condenser, potable water evaporated as steam and condensed to form pure, clean water . Inside the condenser there is a cooling system that cools the steam to make it condense. The feed of cooling liquid is monitored in the pipeline. Point level detection ensures that sufficient condensate is present to prevent steam from directly entering the circulation reservoir.


Frequently Asked Questions

Answer

A limit switch is an actuator connected to an electrical switch. When a limit switch is installed in a liquid tank and the liquid makes contact with the actuator, an electrical connection is made, and the switch is turned on/off.

Answer

Capacitive limit switches are used in liquid applications, such as a yeast storage container or mineralization tank.

Answer

They are very straightforward and flexible and can be easily installed into virtually any liquid application. Capacitive level sensors also provide accurate, repeatable information, while being low power consumption devices.

Answer

This depends on your specific application. With a radar sensor, you're able to continuously monitor the amount of liquid in a given tank. Whereas a capacitive limit switch will only trigger when the liquid comes into contact with the sensor. If your application requires constant updates on liquid level, a radar sensor would be a better option. If you only need to know when a liquid has reach a certain level, a capacitive limit switch is a good option.

VEGAPOINT Part Numbers

PART NUMBER Appliation Area Range
P11.XAGI

½" NPT thread, M12 connector, transistor output

From DK > 2
P21.XXXXXAGTIB

½" NPT thread, M12 connector, transistor output, comes with 5m of cable

From DK > 1.5
P23 Call to Configure

½" NPT thread, universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals, tube version, up to 1 m

From DK > 1.5
P24 Call to Configure

½" NPT thread, universal adapter G1* for hygiene adapter M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals

From DK > 1.5

Compatible Controllers

X-410™ | Web-Enabled Programmable Controller

Part number(s): X-410-I, X-410-E

OUTPUTS

Relays: 4

Current: 1A 28VAC, 24VDC

INPUTS

Digital: 4

Type: Optically-Isolated (Shared Ground)

1-Wire Bus: 16

Temperature/Humidity

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Peer-to-peer

Counters: Inputs 1-4

Automatic Reboot

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP, SMTP, Remote Services

X-401™ | Dual Relay and Input Module

Part number(s): X-401-I, X-401-E

OUTPUTS

Relays: 2

Current: 3A 28VAC, 24VDC

INPUTS

Digital: 2

Type: Optically-Isolated

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Peer-to-peer

Counters: Inputs 1-2

Automatic Reboot

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP, SMTP, Remote Services

X-408™ | Web-Enabled Digital Input Module

Part number(s): X-408-I, X-408-E

OUTPUTS

-

INPUTS

Digital: 8

Type: Optically-Isolated

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Peer-to-peer

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP, SMTP, Remote Services

More Information:

Specifications

Warning: May contain chemicals, including Nickel (metallic), known to the State of California to cause cancer and reproductive harm. - www.P65Warnings.ca.gov

Subtotal

SECURE CHECKOUT

Your cart is empty.


Your Cart is currently empty.


View Return Policy View Cart