ControlByWeb
Product Catalog   (435) 750-5999
VEGAPULS C Series Non-guided Radar Sensor | ControlByWeb

The VEGAPULS C Series wired sensors are non-contact, continuous level radar sensors with high protection.

RANGE

Up To 8 Meters

APPLICATION AREA

Axial cable outlet, 4-20 mA output, measuring range up to 8 m, accuracy ±5 mm, PVC cable with 10m length

Configurable: Please contact our sales department for additional options.

IMAGE

VEGAPULS C 11

PRICE

$765.00

Lead Time: 10-12 Weeks

Quantity:

Application Area

The VEGAPULS C Series wired sensors are non-contact, continuous level radar sensors. This sensor line excels at simple measuring tasks, such as tank level and fuel tank level monitoring, wastewater and water treatment, pump stations, and rain overflow basins. The VEGAPULS C Series is best used in any outdoor level monitoring application that requires a a rugged sensor.

Your benefit

  • Exact measurement results independent of medium, process and environmental conditions
  • Low-cost radar sensor for simple measurement tasks
  • Maintenance-free operation due to non-contact 80 GHz radar technology

Tank Level Monitoring

Water Treatment

VEGAPULS sensors are easy to install and operate, and work well in the water/wastewater supply network. These sensors measure the level and pressure accurately and reliably in containers, pipes, filters and reservoirs.

Level measurement in the pure water tank

Non-contact level measurement with radar in the water storage basin. External display and adjustment unit for 4-20 mA/HART sensors.

Wastewater Treatment

Sewage treatment

Sewage plants around the world rely on VEGA measurement technology for their maintenance-free operation and accurate measurement data.

Flow-rate measurement in open channels

The radar sensor measures the flow rate continuously under all weather conditions.

Fuel Tank Level Monitoring

From airports to water treatment plants, businesses can rely on VEGA measurement technology for fuel level monitoring. They are low maintenance and provide high accuracy readings, making them a reliable solution for fast-paced applications.

Non-Contact Fuel Level Monitoring

Measure fuel levels continuously in many different fuel tank sizes and shapes.

Receive notifications via text and email when paired with ControlByWeb IIoT Controllers.


Frequently Asked Questions

Answer

Radar level sensors emit microwaves signals that are reflected back to the sensor by the target surface. The sensor measures the time of flight and calculates a distance from the sensor face. This is then converted to a level measurement based on how the sensor is scaled.

Answer

The VEGAPULS line of radar sensors are rated from ±5 mm to ±2 mm accuracy. Generally speaking, radar sensors are one of the more precise options for non-contact level measurement.

Answer

The primary difference between radar level trasmitters and ultrsonic is the type of signal they emit. Radar sensors use a microwave signal while ultrasonics use sound. Both are effective in different scenarios. Radar transmitters are generally more capable in a wider range of applications. However, ultrasonic sensors tend to be easier to work with as long as they're well suited for the application.

Answer

Radar level transmitters work well with both liquids and solids level measurement. They tend to excel in more difficult applications as they can be finely tuned to the correct surface while ignoring obstacles. However, radar sensors are still a bit more expensive than simpler technologies like ultrasonic. If your application is simple, such as cold, clean water level monitoring, consider an ultrasonic level sensor for a more cost effective solution. Contact us to discuss your specific needs. We'd be happy to help you select the right technology.

VEGAPULS C Series Part Numbers

PART NUMBER Description Range
PSC11.NB

Axial cable outlet, 4-20 mA output, measuring range up to 8 m, accuracy ±5 mm, PVC cable with 10 m length

Up to 8 Meters
PSC21.XXXXXNBHB

Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4-20 mA

Up to 15 Meters
PSC21.XXXXXNBWB

Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, Modbus output

Up to 15 Meters
PSC22.XXXXXNBHB

Lateral cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4-20 mA

Up to 15 Meters
PSC23.XXXXXMBHB

Axial cable outlet, measuring range up to 30 m, accuracy ±2 mm, 4-20 mA

Up to 30 Meters

More Information:

Specifications

Buy Now or Request a Consultation

Click "Buy Online" to view part numbers and pricing, or schedule and free consultation. VEGAPULS C Series is available in, and can be purchased either from us or an Authorized Distributor.

BUY ONLINE


Compatible Controllers

OUTPUTS

DIGITAL I/O: 2

Configurable as relays/digital inputs

INPUTS

Digital Inputs: (See Outputs)

Analog Inputs: 4

Input Range: ±1.28V, ±2.56V, ±5.12V, ±10.24V, 4-20mA, (No external resistors required.)

1-Wire Bus: 16

Temperature/Humidity

Frequency Input: 1

0-20 kHz Frequency

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Counters: Inputs 1-2

Peer-to-peer

Configurable Digital I/O

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP, SMTP, Remote Services

OUTPUTS

-

INPUTS

Analog Inputs: 8

Input Range: ±1.28V, ±2.56V, ±5.12V, ±10.24V, 4-20mA (No external resistors required.)

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Peer-to-peer

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP V1,2C,V3 protocols

X-404™ | Modbus Master Controller

Part number(s): X-404-I

OUTPUTS

-

INPUTS

Modbus Sensors: Up to 32 modbus devices/sensors

1-Wire Bus: Up to 16 temperature/humidity sensors

FEATURES

Email Alerts

Logging

Scheduling

BASIC Interpreter

Peer-to-peer

PROTOCOLS

HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP V1,2C,V3, SMTP

Warning: May contain chemicals, including Nickel (metallic), known to the State of California to cause cancer and reproductive harm. - www.P65Warnings.ca.gov

Subtotal

SECURE CHECKOUT

Your cart is empty.


Your Cart is currently empty.


View Return Policy View Cart